CCS4 open old CCS3 DSP/BIOS project: Difference between revisions

From DSignT Support Database
Jump to navigationJump to search

(Pushed from DSignT Issue Database.)
(Pushed from DSignT Issue Database.)
 
Line 9: Line 9:


== Additional Tags ==
== Additional Tags ==
CCSv4, [[Migrating C2000 Projects from CCSv3.3 to CCSv4|Migrating old projects]]
CCSv4, [[Migrating C2000 Projects from CCSv3.3 to CCSv4|Migrating old projects]],[[Import old CCS project]]


[[Category:CCS4 Usage]]
[[Category:CCS4 Usage]]

Latest revision as of 11:20, 23 March 2012

Problem:

after opening old DSP/BIOS project CCS4 fails to link due to several errors like:

  • run placement fails for object ".abc"
  • absolute symbol "XYZ" being redefined


Solution:

CCS4 already uses all defined sections from database without generating a linker command file. Old DSP/BIOS projects contain automatically generated linker command files. These *.cmd files are imported by CCS4 to the current project and linked again to the current executable. Exclude these files from build for proper link process.

Additional Tags

CCSv4, Migrating old projects,Import old CCS project



Contact Post.png Support Tool.png