Difference between revisions of "XDS100v3 C6747/OMAP-L137 Connection Problem"
From DSignT Support Database
WikiImporter (talk | contribs) |
WikiImporter (talk | contribs) |
||
Line 2: | Line 2: | ||
CCSv5.x XDS100v3 C6747/OMAP-L137 Target Configuration Problems | CCSv5.x XDS100v3 C6747/OMAP-L137 Target Configuration Problems | ||
− | |||
Error Message: | Error Message: |
Latest revision as of 10:32, 29 January 2018
1 Problem
CCSv5.x XDS100v3 C6747/OMAP-L137 Target Configuration Problems
Error Message:
IcePick_C_0: Error connecting to the target: (Error -501 @ 0x0) The built-in scan-path length measurement failed. The built-in scan-path reliability tests cannot be performed without knowledge of the scan-path length. Try specifying the scan-path lengths in the command-line options or board configuration file of this utility or debugger.
2 Solution
Open CCS Target Configuration, Advanced Tab, Connection Properties:
- change Converter Usage (default: 2-pin advanced) to 4-pin standard
- change Target Pin Width (default: 2 JTAG pins) to 4 JTAG pins
alternative:
change Converter Usage to "bypass, mimic XDS100v2"
3 Additional Tags
XDS100 IcePick