Difference between revisions of "XDS100v3 C6747/OMAP-L137 Connection Problem"

From DSignT Support Database
Jump to: navigation, search

 
Line 2: Line 2:
 
CCSv5.x XDS100v3 C6747/OMAP-L137 Target Configuration Problems
 
CCSv5.x XDS100v3 C6747/OMAP-L137 Target Configuration Problems
  
test
 
  
 
Error Message:
 
Error Message:

Latest revision as of 10:32, 29 January 2018

1 Problem

CCSv5.x XDS100v3 C6747/OMAP-L137 Target Configuration Problems


Error Message:

IcePick_C_0: Error connecting to the target: (Error -501 @ 0x0) The built-in scan-path length measurement failed. The built-in scan-path reliability tests cannot be performed without knowledge of the scan-path length. Try specifying the scan-path lengths in the command-line options or board configuration file of this utility or debugger.


Arr u.png    back to top

2 Solution

Open CCS Target Configuration, Advanced Tab, Connection Properties:

- change Converter Usage (default: 2-pin advanced) to 4-pin standard

- change Target Pin Width (default: 2 JTAG pins) to 4 JTAG pins


alternative: change Converter Usage to "bypass, mimic XDS100v2"


Arr u.png    back to top

3 Additional Tags

XDS100 IcePick



Contact Post.png Support Tool.png