XDS100v3 C6747/OMAP-L137 Connection Problem
From DSignT Support Database
Revision as of 11:25, 13 March 2012 by WikiImporter (talk | contribs) (Pushed from DSignT Issue Database.)
reported by | |
hardware | |
software | |
problem | |
status | closed |
solution | yes |
Contents
1 Problem
CCSv5.x XDS100v3 C6747/OMAP-L137 Target Configuration Problems
Error Message:
IcePick_C_0: Error connecting to the target: (Error -501 @ 0x0) The built-in scan-path length measurement failed. The built-in scan-path reliability tests cannot be performed without knowledge of the scan-path length. Try specifying the scan-path lengths in the command-line options or board configuration file of this utility or debugger.
2 Solution
Open CCS Target Configuration, Advanced Tab, Connection Properties:
- change Converter Usage (default: 2-pin advanced) to 4-pin standard
- change Target Pin Width (default: 2 JTAG pins) to 4 JTAG pins
alternative:
change Converter Usage to "bypass, mimic XDS100v2"
3 History
reported
4 Additional Tags
XDS100 IcePick